<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pelco Pulse &#187; Safety relay</title>
	<atom:link href="https://pelcopulse.com/?feed=rss2&#038;tag=safety-relay" rel="self" type="application/rss+xml" />
	<link>https://pelcopulse.com</link>
	<description></description>
	<lastBuildDate>Tue, 31 Dec 2024 13:49:12 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=3.9.40</generator>
	<item>
		<title>SchleicherUSA safety relays for reliable performance in various applications to protect people, equipment and systems.</title>
		<link>https://pelcopulse.com/?p=1728</link>
		<comments>https://pelcopulse.com/?p=1728#comments</comments>
		<pubDate>Wed, 28 Mar 2018 08:12:18 +0000</pubDate>
		<dc:creator><![CDATA[Gretta at Pelcocaz]]></dc:creator>
				<category><![CDATA[Airotronics Timers and Controls]]></category>
		<category><![CDATA[Categories]]></category>
		<category><![CDATA[SchleicherUSA]]></category>
		<category><![CDATA[Door latch]]></category>
		<category><![CDATA[Emergency stop]]></category>
		<category><![CDATA[Safety gate]]></category>
		<category><![CDATA[Safety relay]]></category>

		<guid isPermaLink="false">http://pelcopulse.com/?p=1728</guid>
		<description><![CDATA[<p>Schleicher safety relays meet DIN ISO 13849 and DIN EN 61062 standards. In addition they fulfill the technical requirements for relay technology with positive driven contacts in accordance with EN 50205. All signals from safety sensors, emergency stop buttons and safety interlocks are safely monitored and comply with the machinery directive 2006/42/EC. See Safety Relays&#8230;</p>
<p>The post <a rel="nofollow" href="https://pelcopulse.com/?p=1728">SchleicherUSA safety relays for reliable performance in various applications to protect people, equipment and systems.</a> appeared first on <a rel="nofollow" href="https://pelcopulse.com">Pelco Pulse</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p><a href="http://schleicherusa.com/products-safety.php" target="_blank"><img class="alignright wp-image-1722 size-full" src="http://pelcopulse.com/wp-content/uploads/2018/03/SafetyRelaysSchleicherUSA.jpg" alt="Five Safety Relays" width="300" height="180" /></a></p>
<h3>Schleicher safety relays meet DIN ISO 13849 and DIN EN 61062 standards. In addition they fulfill the technical requirements for relay technology with positive driven contacts in accordance with EN 50205. All signals from safety sensors, emergency stop buttons and safety interlocks are safely monitored and comply with the machinery directive 2006/42/EC.</h3>
<p><a href="http://schleicherusa.com/products-safety.php" target="_blank" rel="noopener">See Safety Relays at SchleicherUSA</a></p>
<h3>EGRESS AND EXITS SAFETY RELAYS</h3>
<p><strong><a href="http://schleicherusa.com/products-safety.php" target="_blank"> <img class="alignleft wp-image-1724" src="http://pelcopulse.com/wp-content/uploads/2018/03/EmergencyDoorLatch.jpg" alt="EmergencySafetyDoor" width="200" height="133" /></a>Automatic<br />
<a href="http://schleicherusa.com/products-safety.php" target="_blank"><img class="alignright wp-image-1726" src="http://pelcopulse.com/wp-content/uploads/2018/03/SafetyDoorLatch.jpg" alt="SafetyDoorLatch" width="200" height="133" /></a>latching/unlatching, operator interaction, safety mats</strong></p>
<p>&nbsp;</p>
<h3>INDUSTRIAL EQUIPMENT SAFETY RELAYS</h3>
<p><strong><a href="http://schleicherusa.com/products-safety.php" target="_blank"><img class="alignleft wp-image-1723" src="http://pelcopulse.com/wp-content/uploads/2018/03/IronerLightCurtain.jpg" alt="Flatwork ironer light curtain" width="200" height="133" /></a>Stop<a href="http://schleicherusa.com/products-safety.php" target="_blank"><img class="alignright wp-image-1725" src="http://pelcopulse.com/wp-content/uploads/2018/03/DrillPressMachines.jpg" alt="Benchmount drilling machines" width="200" height="133" /></a>/start, emergency switches, 2-hand controls, light curtain and laser safety stops</strong></p>
<p>From power plants and factories to manufacturing, transportation and logistics, reliable safety systems are required. Choose SchleicherUSA for proven performance in your safety chain.</p>
<h3>SchleicherUSA safety relays can be specified by the following characteristics<br />
• Types of sensors monitored<br />
• Safety function<br />
• Safety category<br />
• Stop category<br />
• Quantity of safety contacts<br />
• Start function</h3>
<h4></h4>
<p><a href="http://pelcopulse.com/wp-content/uploads/2017/04/SchleicherSafetyRelaysChart.pdf" target="_blank" rel="noopener">Download SafetyRelays reference chart</a><br />
<a title="Schleicher-Product-Overview-Brochure" href="http://pelcopulse.com/wp-content/uploads/2018/03/Schleicher-Product-Overview-Brochure.pdf" target="_blank" rel="noopener">Download SchleicherUSA Product Overview</a><br />
<a title="Safety Relays in Manufacturing, Transportation, Distribution and more" href="http://pelcopulse.com/?p=1342" target="_blank" rel="noopener">For additional applications and details</a>, see Building the Safety Chain<br />
<a title="Safety relays, monitors, switches and automation controls" href="http://pelcopulse.com/?p=1265" target="_blank" rel="noopener">Read more about SchleicherUSA</a>, including Timer Relays, Monitor Relays and Automation.<br />
<a href="http://schleicherusa.com/index.php" target="_blank" rel="noopener">Visit SchleicherUSA</a></p>
<p><em><strong><span style="color: #808080;">A division of Pelco Component Technologies</span></strong></em><br />
<span style="color: #808080;"> Across the US and around the world, OEMs, engineers and product designers choose components from Pelco Component Technologies to control electricity and make things happen at the right time. We call it <strong><em>Putting Power to Work</em></strong>.</span><br />
<span style="color: #808080;"> <a href="https://visitor.constantcontact.com/manage/optin?v=001gYuebWlSSZMUUp8cjeeqMf71FgXc92BK" target="_blank" rel="noopener"><span style="color: #808080;">Sign up for PelcoPulse Email</span></a></span><br />
<span style="color: #808080;"> Call 855-227-3526</span><br />
<span style="color: #808080;"> <a href="http://pelcocaz.com/" target="_blank" rel="noopener"><span style="color: #808080;">Contact Pelco</span></a>    <a href="mailto:info@pelcocaz.com" target="_blank"><span style="color: #808080;">Send us an email</span> </a>   <a href="http://pelcocaz.com/" target="_blank" rel="noopener"><span style="color: #808080;">Pelco Website</span></a>   <a href="http://pelcocaz.com/#pelco-pulse" target="_blank" rel="noopener"><span style="color: #808080;">Pelco Blog</span></a></span></p>
<p><span style="color: #808080;"><a href="http://www.hannovermesse.de/home"><img class="alignleft size-full wp-image-1731" src="http://pelcopulse.com/wp-content/uploads/2018/03/HannoverLogoRed.png" alt="Hannover-Messe logo" width="100" height="101" /></a>See Pelco Component Technologies in Germany at Hannover-Messe, April 23rd to 27th! USA Energy Pavilion, Hall 13, at booth B37/5</span></p>
<p>The post <a rel="nofollow" href="https://pelcopulse.com/?p=1728">SchleicherUSA safety relays for reliable performance in various applications to protect people, equipment and systems.</a> appeared first on <a rel="nofollow" href="https://pelcopulse.com">Pelco Pulse</a>.</p>
]]></content:encoded>
			<wfw:commentRss>https://pelcopulse.com/?feed=rss2&#038;p=1728</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Safety Relays in Manufacturing, Transportation, Distribution and more</title>
		<link>https://pelcopulse.com/?p=1342</link>
		<comments>https://pelcopulse.com/?p=1342#comments</comments>
		<pubDate>Fri, 28 Apr 2017 05:58:34 +0000</pubDate>
		<dc:creator><![CDATA[Gretta at Pelcocaz]]></dc:creator>
				<category><![CDATA[Categories]]></category>
		<category><![CDATA[SchleicherUSA]]></category>
		<category><![CDATA[Safety]]></category>
		<category><![CDATA[Safety Regulations]]></category>
		<category><![CDATA[Safety relay]]></category>

		<guid isPermaLink="false">http://pelcopulse.com/?p=1342</guid>
		<description><![CDATA[<p>Assess and select safety relays from SchleicherUSA to protect personnel and facilities. Schleicher safety relays meet DIN ISO 13849 and DIN EN 61062 standards, and meet technical requirements for relay technology with positive driven contacts in accordance with EN 50205. But which safety relays are suitable for hazard sensors like light curtains or step-on mats?&#8230;</p>
<p>The post <a rel="nofollow" href="https://pelcopulse.com/?p=1342">Safety Relays in Manufacturing, Transportation, Distribution and more</a> appeared first on <a rel="nofollow" href="https://pelcopulse.com">Pelco Pulse</a>.</p>
]]></description>
				<content:encoded><![CDATA[<h2><span style="font-size: 14pt;">Assess and select safety relays from SchleicherUSA to protect personnel and facilities. Schleicher safety relays meet DIN ISO 13849 and DIN EN 61062 standards, and meet technical requirements for relay technology with positive driven contacts in accordance with EN 50205. But which safety relays are suitable for hazard sensors like light curtains or step-on mats? How to match emergency stop, solenoid interlock, two-hand control station and other safety switches with correct relay to prevent injuries? <a href="http://pelcopulse.com/?attachment_id=1378" target="_blank">Find out here.</a><br />
</span></h2>
<div id="attachment_1358" style="width: 310px" class="wp-caption alignleft"><a href="http://pelcopulse.com/wp-content/uploads/2017/04/DangerHazard.jpg"><img class="size-medium wp-image-1358" src="http://pelcopulse.com/wp-content/uploads/2017/04/DangerHazard-300x200.jpg" alt="Prevent injuries with safety relays" width="300" height="200" /></a><p class="wp-caption-text"><span style="font-size: 8pt;">Prevent injuries with safety relays</span></p></div>
<h2></h2>
<p>Even Safe Design doesn’t eliminate all hazards, so technical safeguarding is needed. <strong><span style="color: #333399;">The goal of the Safety Chain</span></strong> is to prevent persons from coming into contact with hazards, or to reduce hazards to a safe state before a person can come into contact with them.</p>
<p><strong><span style="color: #333399;">Typical Hazards include</span></strong> shearing, cutting, catching, crushing and other impact injuries, as well as electrocution, burns, and exposure to dangerous substances.<br />
<strong><span style="color: #333399;">Risk Assessment sensors</span> </strong>in industrial applications monitor machine limits such as Speed, Load and Temperature. Performance outside of proscribed settings or limits activates the Safety Chain.<br />
<strong><span style="color: #333399;">The Safety Chain</span></strong> consists of Input&gt;Logic&gt;Output components, in other words, Safeguard &gt; Safety Relay &gt; Contactor, to cut power or safely power down in a response to a given activity, malfunction or change.<br />
<img class="alignnone wp-image-1352" src="http://pelcopulse.com/wp-content/uploads/2017/04/TimeDelayWorkView.jpg" alt="TimeDelaySafetyRelay" width="100" height="98" /><img class="alignnone wp-image-1351" src="http://pelcopulse.com/wp-content/uploads/2017/04/SafetyMat.jpg" alt="SafetyMatSafetyRelay" width="100" height="98" /><img class="alignnone wp-image-1350" src="http://pelcopulse.com/wp-content/uploads/2017/04/NoGoFenceLightCurtain.jpg" alt="SafetyFenceSafetyRelay" width="120" height="120" /><img class="alignnone wp-image-1349" src="http://pelcopulse.com/wp-content/uploads/2017/04/LightCurtain.jpg" alt="LightCurtainSafetyRelay" width="100" height="100" /><img class="alignnone wp-image-1348" src="http://pelcopulse.com/wp-content/uploads/2017/04/ConditionalSwitch.jpg" alt="ConditionalSwitchSafetyRelay" width="100" height="100" /><img class="alignnone wp-image-1344" src="http://pelcopulse.com/wp-content/uploads/2017/04/2HandSwitch.jpg" alt="TwoHandSwitchSafetyRelay" width="100" height="100" /><br />
<strong><span style="color: #333399;">Safeguarding Components</span></strong><br />
Safety Sensors, Actuators or Switches are active or passive and include Emergency Stop Switch, Two-hand Control Station, Conditional enabling switch, Contact Fence or Gate, Light Curtain (senses break by hand or clothing), Step-on Safety Mat (detects entry to hazardous area), as well as Magnetic switch, Solenoid interlock and Holdup detection.</p>
<div id="attachment_1359" style="width: 210px" class="wp-caption alignright"><a href="http://pelcopulse.com/wp-content/uploads/2017/04/PackagingSafety.jpg"><img class="wp-image-1359" src="http://pelcopulse.com/wp-content/uploads/2017/04/PackagingSafety-300x200.jpg" alt="Sensors and safety relays in packaging machine" width="200" height="133" /></a><p class="wp-caption-text"><span style="font-size: 8pt;">Safety relays in packaging machine</span></p></div>
<p><strong><span style="color: #333399;">Signals from safeguarding components</span></strong> (sensors) are typically monitored by safety relays or safety PLCs (programmable logic control).<br />
Various relay functions are required for various types of faults.</p>
<div id="attachment_1357" style="width: 210px" class="wp-caption alignnone"><a href="http://pelcopulse.com/wp-content/uploads/2017/04/FactorySafety.jpg"><img class="wp-image-1357" src="http://pelcopulse.com/wp-content/uploads/2017/04/FactorySafety-300x204.jpg" alt="Custom safety chain in factory" width="200" height="136" /></a><p class="wp-caption-text"><span style="font-size: 8pt;">Custom safety chain in factory</span></p></div>
<p><strong><span style="color: #333399;">SchleicherUSA safety relays can be specified by the following characteristics</span></strong><br />
• Types of sensors monitored<br />
• Safety function<br />
• Safety category<br />
• Stop category<br />
• Quantity of safety contacts<br />
• Start function<br />
<a href="http://pelcopulse.com/?attachment_id=1378" target="_blank">Download SafetyRelays reference chart</a></p>
<p><a href="http://schleicherusa.com/products-safety.php"><img class="alignleft size-medium wp-image-777" src="http://pelcopulse.com/wp-content/uploads/2015/12/SchleicherUSA-Logo-sml-300x70.png" alt="SchleicherUSA Automation and Safety Solutions" width="300" height="70" /></a></p>
<hr width="60%" />
<h3><strong><span style="color: #333399;">Safety Circuits</span></strong><br />
<a href="http://pelcopulse.com/wp-content/uploads/2017/04/Category2Circuit.png"><img class="alignright wp-image-1345" src="http://pelcopulse.com/wp-content/uploads/2017/04/Category2Circuit-300x198.png" alt="Category2Circuit" width="200" height="132" /></a>Sensor input Categories B, 1, 2: Single-channel actuation using 1 switching element.<br />
<span style="font-size: 10pt; color: #999999;">Category 2 circuits detect faults by periodic testing at suitable intervals. The safety function can be lost between the periodic tests.</span></h3>
<h3><a href="http://pelcopulse.com/wp-content/uploads/2017/04/Category3Circuit.png"><img class="alignright wp-image-1346" src="http://pelcopulse.com/wp-content/uploads/2017/04/Category3Circuit-300x165.png" alt="Category3Circuit" width="200" height="110" /></a>Sensor input Category 3: Two-channel actuation without cross monitoring, using 2 switching elements.<br />
<span style="font-size: 10pt; color: #999999;"> Category 3 circuits ensure the safety function, in the presence of a single fault, for example by employing two (redundant) channels. Loss of the safety function can occur in the case of an accumulation of faults.</span></h3>
<h3><a href="http://pelcopulse.com/wp-content/uploads/2017/04/Category4Circuit.png"><img class="alignright wp-image-1347" src="http://pelcopulse.com/wp-content/uploads/2017/04/Category4Circuit-300x165.png" alt="Category4Circuit" width="200" height="110" /></a>Sensor input Category 4: Two-channel actuation with cross monitoring, using 2 switching elements.<br />
<span style="font-size: 10pt; color: #999999;">Category 4 circuits ensure that the safety function is always available even in the case of one or more faults, usually by employing both input and output redundancy, together with a feedback loop for continuous monitoring of the outputs.</span></h3>
<p><strong><span style="color: #333399;">Plan your Safety Chain</span></strong> with SchleicherUSA Safety Relays and help from our experts.<br />
<strong><span style="color: #333399;">Call 800-321-9539</span></strong></p>
<p><a href="http://schleicherusa.com/" target="_blank">Visit the SchleicherUSA website</a><br />
<a href="http://schleicherusa.com/products-safety.php" target="_blank">See Safety Relays and choose datasheets for download</a><br />
<a href="mailto:info@pelcocaz.com" target="_blank">Contact us for assistance</a><br />
<a href="http://www.schleicherusa.com/pdfs/Schleicher-Product-Overview.pdf">Download the Schleicher Automation and Safety Soluctions product overview</a></p>
<p><strong><span style="color: #333399;">A division of Pelco Component Technologies<br />
</span></strong>Across the US and around the world, OEMs, engineers and product designers choose components from <em><strong>Pelco Component Technologies </strong></em>to control electricity and make things happen at the right time. We call it <em><strong>Putting Power to Work</strong></em>.</p>
<p><strong><a href="http://visitor.constantcontact.com/d.jsp?m=1102821892131&amp;p=oi" target="_blank"><span style="color: #f6735c;">Sign up for PelcoPulse Email</span></a></strong><br />
<span style="font-size: 10pt;"><strong>Call 855-227-3526</strong></span><br />
<strong><a href="http://pelcocaz.com/#quick-contact" target="_blank"><span style="color: #f6735c;">Contact Pelco</span></a>    <a href="mailto:info@pelcocaz.com" target="_blank"><span style="color: #f6735c;">Send us an email</span></a>   <a href="http://pelcocaz.com/" target="_blank"> <span style="color: #f6735c;">Pelco Website</span></a>   <a href="http://pelcopulse.com/" target="_blank"><span style="color: #f6735c;">Pelco Blog</span></a></strong></p>
<p>The post <a rel="nofollow" href="https://pelcopulse.com/?p=1342">Safety Relays in Manufacturing, Transportation, Distribution and more</a> appeared first on <a rel="nofollow" href="https://pelcopulse.com">Pelco Pulse</a>.</p>
]]></content:encoded>
			<wfw:commentRss>https://pelcopulse.com/?feed=rss2&#038;p=1342</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Safety relays, monitors, switches and automation controls</title>
		<link>https://pelcopulse.com/?p=1265</link>
		<comments>https://pelcopulse.com/?p=1265#comments</comments>
		<pubDate>Thu, 16 Mar 2017 06:45:39 +0000</pubDate>
		<dc:creator><![CDATA[Gretta at Pelcocaz]]></dc:creator>
				<category><![CDATA[Categories]]></category>
		<category><![CDATA[SchleicherUSA]]></category>
		<category><![CDATA[Automation]]></category>
		<category><![CDATA[Current sensor]]></category>
		<category><![CDATA[Innovation]]></category>
		<category><![CDATA[Multifunction relay timer]]></category>
		<category><![CDATA[Order Components]]></category>
		<category><![CDATA[Precision controls]]></category>
		<category><![CDATA[Safety relay]]></category>
		<category><![CDATA[Time delay relay]]></category>

		<guid isPermaLink="false">http://pelcopulse.com/?p=1265</guid>
		<description><![CDATA[<p>Schleicher stands for quality, innovation and eight decades of experience. It is renowned worldwide for high performance control systems, safety relays and timers, electronic engineering services (EES) and electronic manufacturing services (EMS). In 2015, SchleicherUSA was established to bring safety relays, monitors, switches and automation controls to the North American marketplace. SchleicherUSA website    Contact Schleicher  &#8230;</p>
<p>The post <a rel="nofollow" href="https://pelcopulse.com/?p=1265">Safety relays, monitors, switches and automation controls</a> appeared first on <a rel="nofollow" href="https://pelcopulse.com">Pelco Pulse</a>.</p>
]]></description>
				<content:encoded><![CDATA[<h3>Schleicher stands for quality, innovation and eight decades of experience. It is renowned worldwide for high performance control systems, safety relays and timers, electronic engineering services (EES) and electronic manufacturing services (EMS). In 2015, SchleicherUSA was established to bring safety relays, monitors, switches and automation controls to the North American marketplace.</h3>
<p><a href="http://schleicherusa.com/"><img class="alignleft wp-image-777 size-medium" src="http://pelcopulse.com/wp-content/uploads/2015/12/SchleicherUSA-Logo-sml-300x70.png" alt="SchleicherUSA Automation and Safety Solutions" width="300" height="70" /></a><hr class="symple-divider solid  symple-all" style="margin-top: 2px;margin-bottom: 2px;" />
<strong><a href="http://schleicherusa.com/" target="_blank"><span style="color: #f6735c;">SchleicherUSA website</span></a>    <a href="http://schleicherusa.com/" target="_blank"><span style="color: #f6735c;">Contact Schleicher</span></a>   Call 800-321-9539</strong></p>
<h3>SchleicherUSA Relay Technology</h3>
<p>Choose Schleicher safety, timing and measurement components for machinery and systems.  Get sophisticated solutions in convenient and compact DIN rail type housings.</p>
<p><strong><span style="color: #2d73b8;">Additional advantages:</span></strong></p>
<ul>
<li>Committed after-sales service</li>
<li>Active life-cycle management</li>
<li>Adjustments, expansions and alterations at any time</li>
<li>Guaranteed service life of more than 25 years</li>
</ul>
<p><span style="color: #f6735c;"><a href="www.schleicherusa.com/pdfs/Schleicher-Product-Overview.pdf"><span style="color: #f6735c;"><strong>Download Products Overview</strong></span></a></span></p>
<h3>Safety Relays</h3>
<p>To ensure maximum protection for operators and machines, safety relays must be easy to use and very reliable. High quality SchleicherUSA safety relays meet DIN ISO 13849 and DIN EN 61062 standards. In addition they fulfill the technical requirements for relay technology with positive driven contacts in accordance with EN 50205.<a href="http://schleicherusa.com/products-safety.php" target="_blank"><img class="alignright wp-image-1321 size-full" src="http://pelcopulse.com/wp-content/uploads/2017/03/SafetyRelay.jpg" alt="SchleicherUSA Safety Relays and Switches" width="300" height="250" /></a></p>
<p><strong><span style="color: #2d73b8;">Applications include:</span></strong></p>
<ul>
<li>Emergency stop</li>
<li>Safety gate</li>
<li>Safety mats, strips, edges, bumpers</li>
<li>Light grids, inductive sensors</li>
<li>Controlled shutdown</li>
<li>Access delay</li>
<li>Type III C two-handed monitoring</li>
<li>Contact output extension</li>
</ul>
<p><a href="http://schleicherusa.com/products-safety.php" target="_blank"><span style="color: #f6735c;"><strong>Show me Safety Relays</strong></span></a></p>
<h3>Timer Relays and Switching Devices</h3>
<p>Timer relays and switching devices are intermediaries between the intelligent logic level of the computer or other control devices and the machines or systems doing the work. Relays and switches provide high-performance isolation between the low-voltage range of the intelligent logic, and the high power consumption of the machine operation.<br />
SchleicherUSA supplies a wide range of timer and switching relays with various features and functions, ensuring precise component selection to meet the requirements of your application.<a href="http://schleicherusa.com/products-timers.php" target="_blank"><img class="alignright wp-image-1323 size-full" src="http://pelcopulse.com/wp-content/uploads/2017/03/TimerRelays.jpg" alt="SchleicherUSA Timer Relays and Switches" width="300" height="250" /></a></p>
<p><strong><span style="color: #2d73b8;">Features include:</span></strong></p>
<ul>
<li>Multifunction, Single function, Multi-range, Single-range and Fixed time</li>
<li>On-delay, Off-delay, On-delay and Off-delay, wiper controls</li>
</ul>
<p><strong><span style="color: #2d73b8;">Relay functions include:</span></strong></p>
<ul>
<li>Impulse generator</li>
<li>Blinker relay</li>
<li>Relay for a star-delta/wye-delta switch</li>
<li>Pulse counter</li>
<li>Coupling relays</li>
<li>Latching relays</li>
</ul>
<p><a href="http://schleicherusa.com/products-timers.php" target="_blank"><span style="color: #f6735c;"><strong>Show me Timer Relays</strong></span></a></p>
<h3>Measurement Relays and Monitoring Devices</h3>
<p>Rapid-response measuring and monitoring devices continuously review and evaluate all electrical and physical states. These components facilitate quick and accurate response in the event of an error. Proactive switch-off of the affected part of the system prevents damage to other unit components.<br />
SchleicherUSA offers measurement and monitoring relays for all potential configurations.<a href="http://schleicherusa.com/products-measurement.php"><img class="alignright size-full wp-image-1322" src="http://pelcopulse.com/wp-content/uploads/2017/03/MeasurementMonitor.jpg" alt="SchleicherUSA Measurement and Monitor Relays" width="300" height="250" /></a></p>
<p><strong><span style="color: #2d73b8;">Current and voltage monitor functions:</span></strong></p>
<ul>
<li>Detection of low or excess voltages</li>
<li>Detection of low or excess currents</li>
</ul>
<p><strong><span style="color: #2d73b8;">Phase Monitor functions:</span></strong></p>
<ul>
<li>Phase sequence and phase failure monitoring</li>
<li>Detection of incorrect phase sequence</li>
<li>Detection of dangerous phase voltage imbalance</li>
<li>Detection of voltage feedback</li>
</ul>
<p><strong><span style="color: #2d73b8;">Safety and Protective Monitor functions:</span></strong></p>
<ul>
<li>Protection of people and machines</li>
<li>Immediate interruption of the energy supply</li>
<li>Monitoring of two-hand applications</li>
<li>Monitoring of safety guards</li>
</ul>
<p><a href="http://schleicherusa.com/products-measurement.php" target="_blank"><span style="color: #f6735c;"><strong>Show me Monitor Relays</strong></span></a></p>
<p><strong><a href="http://schleicherusa.com/" target="_blank"><span style="color: #f6735c;">SchleicherUSA website</span></a>    <a href="http://schleicherusa.com/" target="_blank"><span style="color: #f6735c;">Contact Schleicher</span></a>   Call 800-321-9539</strong></p>
<h3>SchleicherUSA Automation</h3>
<p>Welcome to advanced open system machine automation! Schleicher provides powerful modular control systems for all requirements of modern machine manufacturing.<br />
Open systems allow individual functions to be realized for high-performance machines, with faster and simpler connections between networks or various components. SchleicherUSA automation incorporates the latest CNC and PLC technologies and uses EtherCAT®, Sercos® and the newest Windows variants, among others.<br />
Schleicher systems are maintenance-free, robust and flexible. Installations are tailored to individual customers and programmed for long life and simple operation.</p>
<p><a href="http://www.schleicherusa.com/pdfs/Schleicher-Product-Overview.pdf"><span style="color: #f6735c;"><strong>Download Products Overview</strong></span></a></p>
<h3>Controls<a href="http://schleicherusa.com/products-controllers.php"><img class="alignright size-full wp-image-1319" src="http://pelcopulse.com/wp-content/uploads/2017/03/Controls.jpg" alt="SchleicherUSA automation controls" width="200" height="150" /></a></h3>
<p>Schleicher XCx automation systems and components provide a modular structure for application-adapted design. From an entry-level rack-based control system, expansion modules and racks, and additional controls can handle up to 128 modules on a maximum of 8 racks with full system extension over 4000 I/O points.</p>
<p><a href="http://schleicherusa.com/products-controllers.php" target="_blank"><span style="color: #f6735c;"><strong>Show me Controllers</strong></span></a></p>
<h3>I/O Systems<a href="http://schleicherusa.com/products-iosystems.php" target="_blank"><img class="alignright wp-image-1318 size-full" src="http://pelcopulse.com/wp-content/uploads/2017/03/RIO-io.jpg" alt="SchleicherUSA RIO Input output" width="200" height="150" /></a></h3>
<p>With increases in plant complexity, peripheral connection via fieldbus has become standard in most automated infrastructures. The “RIO” I/O system from SchleicherUSA is equipped with comprehensive modules that pick up, route and output the necessary process-specific signal mix..</p>
<p><a href="http://schleicherusa.com/products-iosystems.php" target="_blank"><span style="color: #f6735c;"><strong>Show me I/O Systems</strong></span></a></p>
<h3>Human Machine Interface<a href="http://schleicherusa.com/products-hmi.php hmi and software"><img class="alignright size-full wp-image-1316" src="http://pelcopulse.com/wp-content/uploads/2017/03/HMI.jpg" alt="SchleicherUSA HMI Human Machine Interface" width="200" height="150" /></a></h3>
<p>The ProNumeric OP50 is an optimized HMI device employing the Sercos III and EtherCat realtime field bus systems, combined in a single hand-held control. At last a single unit connects to the controls of different manufacturers.<br />
<a title="Simplified GUI and precision controls for complex CNC manufacturing" href="http://pelcopulse.com/wp-content/uploads/2015/12/SchleicherUSA-Mikromat120215.pdf"><strong><span style="color: #f6735c;">For more details see Whitepaper</span></strong></a> <em>Simplified GUI and Precision Controls for Complex CNC Manufacturing</em></p>
<p><a href="http://schleicherusa.com/products-hmi.php%20hmi and software" target="_blank"><span style="color: #f6735c;"><strong>Show me HMI and Software</strong></span></a></p>
<h3>Software<a href="http://schleicherusa.com/products-hmi.php hmi and software"><img class="alignright size-full wp-image-1317" src="http://pelcopulse.com/wp-content/uploads/2017/03/Software.jpg" alt="SchleicherUSA Automation software" width="200" height="150" /></a></h3>
<p><strong>SIM:ONE SIMULATION SOFTWARE</strong> Users can test and analyze CNC programs and machine movement sequences on their own PC with Sim:one software. Potential risks can be detected and eliminated at an early stage, and productivity of the machine can be maximized.<br />
<strong>SCHLEICHER GRED Schleicher GRED</strong> is a compaction software for production or logistics systems that process large quantities of real-time data. GRED reduces the size of the retained data and therefore needs less physical memory capacity; NV-RAM, hard disk and RAM share storage and access while GRED runs in the background without impairing the application.</p>
<p><a href="http://pelcopulse.com/?p=755" target="_blank"><span style="color: #f6735c;"><strong>Read about Schleicher’s automated CNC control system for MIKKROMAT</strong></span></a></p>
<p><strong><a href="http://schleicherusa.com/" target="_blank"><span style="color: #f6735c;">SchleicherUSA website</span></a>    <a href="http://schleicherusa.com/" target="_blank"><span style="color: #f6735c;">Contact Schleicher</span></a>   Call 800-321-9539</strong></p>
<h3>A division of Pelco Component Technologies</h3>
<h4>Across the US and around the world, OEMs, engineers and product designers choose components from <em><strong>Pelco Component Technologies </strong></em>to control electricity and make things happen at the right time. We call it <em><strong>Putting Power to Work</strong></em>.</h4>
<p><strong><a href="http://visitor.constantcontact.com/d.jsp?m=1102821892131&amp;p=oi" target="_blank"><span style="color: #f6735c;">Sign up for PelcoPulse Email</span></a></strong><br />
<span style="font-size: 14pt;"><strong>Call 855-227-3526</strong></span><br />
<strong><a href="http://pelcocaz.com/#quick-contact" target="_blank"><span style="color: #f6735c;">Contact Pelco</span></a>    <a href="mailto:info@pelcocaz.com" target="_blank"><span style="color: #f6735c;">Send us an email</span></a>   <a href="http://pelcocaz.com/" target="_blank"> <span style="color: #f6735c;">Pelco Website</span></a>   <a href="http://pelcopulse.com/" target="_blank"><span style="color: #f6735c;">Pelco Blog</span></a></strong></p>
<p>&nbsp;</p>
<h3></h3>
<p>The post <a rel="nofollow" href="https://pelcopulse.com/?p=1265">Safety relays, monitors, switches and automation controls</a> appeared first on <a rel="nofollow" href="https://pelcopulse.com">Pelco Pulse</a>.</p>
]]></content:encoded>
			<wfw:commentRss>https://pelcopulse.com/?feed=rss2&#038;p=1265</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
